1、排烟罩装置的烟管直接穿过外墙至室外,应该在室外排气口设置避免污染环境和避风的构件。共用竖向烟道衔接的吸油烟机,它的竖向烟道的断面应根据所担负的排气量计算断定。

  1. The smoke pipe installed in the smoke hood of Ji'nan hotel is directly through the exterior wall, so it should be installed in the outdoor air outlet to prevent the pollution of the environment and avoid the wind. A fume exhauster which is connected with a vertical flue, and the vertical flue section thereof shall be calculated and determined according to the amount of the exhaust discharged.

  2、酒店排烟罩装置顶吸式的装置高度应该在燃气炉灶上方至少65 厘米的当地,在65-75 厘米之间是比较适宜的。

  2, kitchen hood installation, overhead suction installation height should be at least 65 centimeters above the gas stove place, between 65-75 cm is more appropriate.

  3、厨房排烟罩装置的墙体,它的结构和资料都应该要有满足的强度。排烟管、风管的外墙开口,可采用砌筑预制带洞混凝土块或预埋钢管留洞办法。保温墙(最好要用空心砖)与正常墙壁的装置办法一样,如果墙面不可健壮的话,那么就要用木板或其他资料进行加固。

  3, the kitchen smoke hood installed wall, its structure and material should have enough strength. The opening of the outer wall of the smoke pipe and the air duct can be made of prefabricated prefabricated concrete blocks with holes or a buried pipe. Insulation walls (preferably with hollow bricks) are the same as those for normal walls. If the walls are not strong enough, use wood or other materials to reinforce them.

  厨房设备通风问题

  Ventilation of kitchen equipment

  1、主排烟管道通风面积不可,气体流速过大.根据工程阅历,排烟主管道内风速不能逾越15m/s.不然在工作一个期间往后(如一年往后)很简单构成排烟系统不通畅.在油烟净化器的工作实践中,大多数案例都是因排烟罩管道通风面积缺乏导致的不通畅,管道内气体的流速都在15m/s以上.

  1, the main exhaust pipe ventilation area no gas flow rate is too large. According to the engineering experience, the main exhaust air velocity in pipe can not exceed 15m/s. or during the operation of a future (such as one year in the future) is very simple form of exhaust system is not intelligible. In operation practice of oil smoke purifier, most cases are not to know due to the exhaust pipe ventilation area, the gas flow rate is above 15m/s.

  2、排烟管道因为要穿过建筑梁而使管道通风截面积变小,截面上阻力增加,构成气流不通畅.

  2, the exhaust pipe passes through the beam because the building ventilation pipe cross-sectional area smaller, add resistance to form air section, don't know.

  3、排烟管道在穿过建筑梁或逃避其它设备管道时,排烟管道中的一段会低于整体排烟管道平面.在运用一段时间后,因为油水混合物会积聚在较低的那段排烟管道中,直接影响排烟通畅.

  3, the exhaust pipe through the construction of beam or other equipment from the pipeline, a section of the exhaust pipe will be lower than the plane of the exhaust pipe. In use after a period of time, because the oil-water mixture will accumulate during the exhaust pipe in the low smoke, directly affect the smooth.

  4、不同楼层的厨房油烟通过同一主管道排出,离出口近的楼层厨房排烟效果较好,而较低楼层的厨房排烟不通畅.

  4, different floors of the same kitchen after discharge from the exhaust main pipe, good effect of export floor near the kitchen, and the kitchen smoke lower floors don't know.

  感谢新老客户对本公司产品的信赖和厚爱。我们将继往开来,排烟罩以高质量的产品、优惠的价格及诚信的效劳与您互利双赢,共创辉煌!公司整体员工竭诚欢迎您的光临指导

  Thank the old and new customers for the trust and love of our products. We will carry on the future, Ji'nan Hotel smoke hood, with high quality products, preferential prices and good service, and your mutual benefit and win-win, and create brilliant! Company staff sincerely welcome your visit and guidance